U-Blot® Human Protein Oxidation Array G8000

U-Blot® Human Protein Oxidation Array G8000
U-Blot® Human Protein Oxidation Array G8000
$9,999.00
SKU: WT9605A-G8000-8

Specification: 8 Sample Kit

Stock: In stock

Product details, specifications, documents, and related products are available from the catalog record. Learn more

Product information

Protein Oxidation has been linked to aging, cancer and other diseases. The Human Protein Oxidation Antibody Array 8000 is specifically designed for simultaneous identification of the relative levels of oxidation of 8000 different human proteins in cell lysate, culture supernatant, serum, plasma and other biological samples. By monitoring the changes in protein oxidation in your experimental model system, you can verify oxidative damage without spending excess time and effort performing an analysis of immunoprecipitation and/or Western Blot. The Human Protein Oxidation Antibody Array utilizes the 'biotin probes' method to biotin label carbonyl groups of oxidized proteins. In this method, the biotin probes first react with carbonyl groups of oxidized proteins to form unstable Schiff bases, which are then further reduced to more stable amines. The biotin labeled sample then is added into antibody array glass slide wells. The antibody array slide wells are washed. After incubation with a fluorescent dye-conjugated streptavidin (Cy3 equivalent), the slides can then be imaged using a laser scanner, such as the Axon GenePix, using the Cy3 channel.

Product Overview

Catalog No.
WT9605A-G8000-8
SKU
WT9605A-G8000-8
Category
Oxidation
Product Type
Other
Size
8 Sample Kit
Stock Status
In stock
Available Stock
20
Minimum Order Quantity
1

Storage & Compliance

Research Use Only
Yes

Additional Specifications

Size
8 Sample Kit
Species
Human
Compatible Sample Types
Cell Culture Supernatants, Plasma, Serum, Tissue Lysates, Cell Lysates
Quantitative/Semi-Quantitative
Semi-Quantitative
Number of Targets Detected
8000
Solid Support
Glass Slide
Design Principle
Label-based
Method Of Detection
Fluorescence Laser Scanner
Research Area
Post-Translational Modifications, Oxidative Stress
Introduction
Protein Oxidation has been linked to aging, cancer and other diseases. The Human Protein Oxidation Antibody Array 8000 is specifically designed for simultaneous identification of the relative levels of oxidation of 8000 different human proteins in cell lysate, culture supernatant, serum, plasma and other biological samples. By monitoring the changes in protein oxidation in your experimental model system, you can verify oxidative damage without spending excess time and effort performing an analysis of immunoprecipitation and/or Western Blot. The Human Protein Oxidation Antibody Array utilizes the 'biotin probes' method to biotin label carbonyl groups of oxidized proteins. In this method, the biotin probes first react with carbonyl groups of oxidized proteins to form unstable Schiff bases, which are then further reduced to more stable amines. The biotin labeled sample then is added into antibody array glass slide wells. The antibody array slide wells are washed. After incubation with a fluorescent dye-conjugated streptavidin (Cy3 equivalent), the slides can then be imaged using a laser scanner, such as the Axon GenePix, using the Cy3 channel.
Product Features
High sensitivity and specificity;Low sample volume (10-100 µl per array);Large dynamic range of detection;Compatible with most sample types;Test 4 or 8 samples on each slide;Suitable for high-throughput assays
Suggested Application
Multiplexed Protein Detection; Detection of Relative Protein Expression; Detecting Patterns of Cytokine Expression; Biomarker Screening; Identifying Key Factors; Confirming a Biological Process
Kit Components
Glass Slide(s);Blocking Buffer;Cy3 equivalent‑Conjugated Streptavidin;20X Wash Buffer I Concentrate;20X Wash Buffer II Concentrate;Wash Buffer III;2X Cell Lysis Buffer Concentrate;Protease Inhibitor Cocktail;Oxidation Buffer A;Oxidation Labeling Reagent;Oxidation Stabilizing Reagent;Centrifugal Filter Unit;Adhesive film
Other Materials Required
Desalting column or dialysis membrane;1.5 mL microcentrifuge tubes;15 mL tubes (polypropylene);10 mL graduated cylinders (X2);Benchtop centrifuge and microcentrifuge (4°C);Precision pipettes to deliver 2 µl to 1 ml volumes;Adjustable 1‑25 ml pipettes for reagent preparation;Water bath or heat block;Shaker;Laser scanner for fluorescence detection;Aluminum foil;Distilled water;Plastic box;50 ml Centrifuge tube;Isopropanol (2‑propanol)
Protocol Outline
1.Dry the Glass Slide;2.Blocking and Incubation;3.Fluorescence Detection
Storage/Stability
Upon receipt, the kit should be stored at ≤-20°C. Please use within 6 months from the date of shipment.

Tech Support

ucallm

01

Documents

Datasheet, COA, SDS, and protocol files can be requested from technical support.

06

Contact Support

Emailinfo@mail.ucallm.com

Phone+(1)-866-986-9598

WeChat / IMUcallm-Tech

HoursMonday-Friday 09:00-18:00 CST

Request Technical Support
Keywords:Oxidation